Quick report
Entered to bowl around 1pm yesterday 12/3. Observed shin to knee deep unconsolidated powder sitting on top of 1 F hard bed surface. Little to no wind in the bowl throughout the afternoon. First hand sheer test low in the apron of chute showed stable results with much effort needed to initiate a layer to fail around 25 cm below the surface. Second hand sheer around the choke in chute yielded slightly less stable snow with a failure also around 25 cm down where the snow changed from 1F back to 4F.