Quick report
No cracking. We did hear on loud whoomph while we were transitioning on flat terrain Dug a pit at 8745ft in Tornak peak, aspect 12 deg, slope angle about 20-22 deg. ECT 0, whole column fell out while we were cutting the back. Failure was on the several inches of sugar snow beneath a right side up dense 2ft thick slab
Avalanche
North facing slopes around 8000ft