Quick report
There was a weak layer observed at 40 cm. An Extended Column Test and Compression test was performed. ECTP17@40cm, CT 15@ 40 cm, and a complete column failure at the observed ice layer with a CT20@ 1cm or near ground. Given our findings, caution should be exercised on North and East facing aspects as high winds and temperature fluctuations continue.
Weather
- Air Temp
- 32
- Cloud Cover
- few
- Wind Loading
- moderate
Snowpack
Snow depth measured was 70cm with varying faceted layers ranging from solid facets near the surface, to rounded facets near the ground. A 1cm layer of ice also lays on the ground. We found the problematic layer to be at 40cm. Test was performed at 9480' on a Northeast facing aspect below timberline. Previous signs of wind loading were also present.


